SINGLE TISSUE, SINGLE FREQUENCY

Blood @ 2000000 Hz

Tissue
name
Frequency
[Hz]
Conductivity
[S/m]
Relative
permittivity
Loss
tangent
Wavelength
[m]
Penetration
depth [m]
Blood 2000000 0.92605 1680.7 4.9523 2.1019 0.40883

magenta ball Top of document
IFAC-CNR, Florence (Italy), 1997-2021.

Application prepared by Daniele Andreuccetti, Roberto Fossi and Caterina Petrucci, based on the parametric model for the calculation of the dielectric properties of body tissues developed by C.Gabriel and collegues at the Brooks Air Force Base, U.S.A. (see References).