Table 8.3. Whole-Body Average SAR For Saline-Filled Figurines Under Near-Field Exposure Conditions. Experimental Frequency = Simulated Frequency x (Height Of Man/Height Of Figurine) (Chatterjee et al., 1982b)




Simulated
Frequency
for Man
(MHz)





Model
Size
(cm)





Experimental
Frequency
(MHz)
Physical Parameters
for the Fields at
the Simulated
Frequency (m)

*v





*h

Average SAR
(±SD)
W/kg for Maximum
Ev = 1 V/m rms

Experimental
N = 5





Empirical
Equation



SAR for
Planewave
Irradiation
(W/kg;)+
7120.36100.141.28
1.0 (±0.029)
1.2
58.4
7720.36630.4841.32
1.7 (±0.029)
1.8
58.6
8820.37600.6221.66
2.6 (±0.081)
3.8
52.0
9625.46630.3881.06
1.4 (±0.075
1.3
48.0
11025.47600.4961.32
2.0 (±0.067)
2.4
39.2
11533.06100.2120.657
0.42 (±0.064)
0.46
36.0
12533.06630.2980.814
0.66 (±0.045)
0.58
33.4
14333.07600.2560.816
0.38 (±0.040)
0.46
35.0
15033.07950.2760.742
0.54 (±0.0035)
0.42
26.0
17640.67600.2070.690
0.20 (±0.050)
0.19
22.6

---------------------------------

* Obtained by measurement.
Average of three measurements; standard deviation less than ±5%, calculated from 4180 T/ (irradiation time in seconds).
Obtained numerically for an incident field of rms magnitude of 1 V/m.